Showing results: 121 - 135 of 160 items found.
-
ESPP-MIT1 Sensor -
ES Systems
ES Systems has developed a series of strain gauge pressure transmitters featuring very good accuracy at a low cost. Each module is based on an all-welded hermetically sealed structure in a single stainless-steel piece. The ESPP-MIT1 is a medium isolated pressure sensor suitable for gas or fluid pressure measurements in harsh industrial or HVAC environments.
-
Futek Advanced Sensor Technology, Inc.
Pressure Sensors manufactured in US by FUTEK Advanced Sensor Technology (AST), one of a handful of companies producing high quality pressure sensors, using metal foil strain gauge technology. Metal foil Strain-gauge technology is one of the most common types of pressure sensors in the market and is also commonly known as pressure transducers.
-
Morehouse Instrument Company Inc.
When high accuracy and low risk are critical, customers rely on Morehouse Ultra-Precision Load Cells. These strain gauge type load cells are often the choice for companies that want their reference standard to have the lowest possible uncertainties. Lower uncertainties allow for shorter set up times, less frequent standard changes, and fewer standards to maintain.
-
Datum Electronics, Ltd.
Cargo Hawk is a non-intrusive SOLAS compliant Container Weight Verification system. Using Datum Electronics highly accurate and patent protected innovative bolton strain gauge sensors, Cargo Hawk seamlessly integrates to new and existing container handling equipment, without the need of introducing expensive high wearing consumable load monitoring hardware.
-
MSXB 067 -
Microstar Laboratories, Inc.
The MSXB 067 Signal Conditioning Expansion Board provides analog signal conditioning for strain gauges, load cells, RTDs, and other resistive sensors. MSXB 067 provides a flexible interface for quarter-bridge, half-bridge, and full-bridge sensors, with two to six wires for each sensor, with or without voltage sense feedback. A small daughterboard supports user-supplied bridge completion resistors.
-
CSS-4/5 -
Chuan Sheng Electronics Co., Ltd.
● Measuring DCA, DCV, ACA, ACV, Hz● Process signal mA, Vdc, Strain Gauge, Potentiometer, Pt100Ω● High accuracy and resolution● User function, easily programmed from the front panel by push-button, and set-point by Dip-Switch● Modular design, and popular input range programmable● Three relay ( Hi / Low / Go ) outputs● Optional excitation supply available
-
Model 3542RA -
Jinan Testing Equipment IE Corporation
Designed primarily for compressive strength tests on rock, concrete and other large compression samples, this model measures axial strain on opposite sides of the test specimen, and the output is an average of the two readings. Gauge lengths from 1 to 8 inches (25 to 200 mm) and measuring ranges from 0.050 to 0.250 inches (1.2 to 6 mm) are available.
-
Futek Advanced Sensor Technology, Inc.
Torque Sensors manufactured in US by FUTEK Advanced Sensor Technology (FUTEK), offering a huge selection of Torque Sensors, utilizing one of the most advanced technologies in the Sensor Industry: Metal foil strain gauge technology.A Torque Sensor, is a transducer that converts a torsional mechanical input into an electrical output signal. Torque Sensor, are also commonly known as a Torque Transducer.
-
Datum Electronics, Ltd.
Datum Electronics load cell amplifier range is designed to increase (or amplify) a signal, generated by a strain gauge load cells with a full bridge connection, pressure transducers or torque sensors, allowing the user to use the data from the load cell in a more efficient and productive way.
-
Magtrol Inc.
Magtrol's Load Monitoring Units are used for measuring load, force and weight from signals generated by strain gauge transducers. Specifically designed for use with Magtrol's Load Measuring Pins and Load-Force-Weight Sensors, the LMU Series provides excitation voltage while conditioning the bridge output signal. Each unit contains DIP-switches and jumpers for greater flexibility and complete adaptability
-
Response Dynamics Vibration Engineering, Inc.
Although strain measurement is often a key part of a root cause diagnosis, our analyses often also involve measurements of other parameters such as acceleration, relative displacement, pressure, temperature, flow, speed, load, dynamic stiffness, etc, to explore multiple parameters that may have a cause/effect relationship with the problem at hand. These measurements form part of a fact based hypothesis for the cause of the problem at hand. We use stain gauge testing and/or stain modeling and analysis, in conjunction with our structural dynamics expertise to characterize all the important pieces of the puzzle that come into play with dynamic strain issues (See Diagnostic Testing).
-
Type 132 -
Datum Electronics, Ltd.
The Type 132 Amplifier is designed to amplify the signal from any load cell with full bridge connection, allowing the user to use the data from the load cell in a more efficient and productive way.The Type 132 Amplifier is designed to interface to a full bridge strain gauge based load cell or similar sensor. It can be calibrated to provide a 0-10V output for a fixed load range from the sensor.
-
Vetek Weighing AB
DTR is a microprocessor based digital indicator, totally autonomousand with input for strain gauge based torque transducers.A ≤±0,02% accuracy makes it possible to be used use in qualitysystems as first or second line sample, periodically calibrated by aSIT center. Measuring system consists of a particularly long-termstable analogue section, of a carrier frequency amplifier whichminimises thermal drifts and of a 16 bits A/D converter whichensures 65.000 internal divisions.
-
Honeywell Sensing & Control
For high-frequency pressure measurements or in applications with severe space limitations, Honeywell Sensotec offers subminiature flush diaphragm pressure sensors in ranges from 0100 psi to 020,000 psi (010 to 01,400 bar). All-welded, machined stainless steel sensing diaphragms ensure ruggedness. Bonded piezoresistive and metal foil strain gauges offer high reliability. Millivolt and optional high-level outputs are compatible with most data acquisition systems.
-
Procter & Chester Measurements Ltd
Radio Telemetry: A transmission of data from a remote source via a radio to a receiving station for recording and analysis. Inductance: A contactless method of supplying power to (in this case) a strain gauge bridge. The signal is then transmitted back to the electronics. Slip Ring: Consists of a conductive band mounted on a shaft and is insulated from it. The wheatstone bridge is connected to the bands (usually four off). Fixed brushes or contacts make contact on to the bands to transfer power to the bridge and signal back to the static instrumentation.